Monographs: Pharmaceutical substances: Artemisinin (Artemisininum)2014-01
C15H22O5 Relative molecular mass. 282.3 Chemical name. (3R,5aS,6R,8aS,9R,12S,12aR)-3,6,9-trimethyloctahydro-3,12-epoxypyrano[4,3-j ]-1,2-benzodioxepin-10(3H)-one; CAS Reg. No. 63968-64-9. Description. Colourless needles or white crystalline powder. Solubility. Practically insoluble in water; very soluble in dichloromethane R; freely soluble in acetone R and ethyl acetate R; soluble in glacial acetic acid R, methanol R and ethanol (~750 g/L) TS. Category. Antimalarial. Storage. Artemisinin should be kept in a well-closed container and protected from light. Requirements Artemisinin contains not less than 97.0% and not more than 102.0% of C15H22O5, calculated with reference to the dried substance. Identity tests
Specific optical rotation. Use a 10 mg/mL solution in dehydrated ethanol R and calculate with reference to the dried substance;
Sulfated ash. Not more than 1.0 mg/g. Loss on drying. Dry to constant mass at 80 °C; it loses not more than 5.0 mg/g. Related substances Carry out the test as described under 1.14.1 Chromatography, High-performance liquid chromatography using the conditions given below under “Assay”. Use solutions (1) and (2) as described below under “Assay”. For solution (3) dilute 1 mL of solution (1) to 100 mL with the mobile phase. Inject separately 20 µL of solutions (1), (2) and (3). Record the chromatograms for about 1.5 times the retention time of artemisinin. In the chromatogram obtained with solution (2) impurity A (artemisitene) is eluted at the relative retention of about 0.79 with reference to artemisinin (retention time about 10 minutes). The test is not valid unless the resolution factor between the peaks due to impurity A and artemisinin is at least 4. The chromatogram obtained with solution (1) may show a peak due to impurity B (9-epi-artemisinin) eluting at a relative retention of about 0.85 with reference to artemisinin. In the chromatogram obtained with solution (1):
Assay Carry out the test as described under 1.14.1 Chromatography, High-performance liquid chromatography using a stainless steel column (15 cm × 4.6 mm) packed with particles of silica gel, the surface of which has been modified with chemically-bonded octadecylsilyl groups (5 µm). As the mobile phase use a 50:50 mixture of acetonitrile R and water R. Prepare the following solutions in the mobile phase. For solution (1) use 5.0 mg of the test substance per mL. For solution (2) use 5.0 mg of artemisinin RS (containing artemisinin and impurity A) per mL. Operate with a flow rate of 1.0 mL per minute. As a detector use an ultraviolet spectrophotometer set at a wavelength of 210 nm. Inject separately 20 µL of solutions (1) and (2). Record the chromatograms for about 1.5 times the retention time of artemisinin. In the chromatogram obtained with solution (2) impurity A (artemisitene) is eluted at the relative retention of about 0.79 with reference to artemisinin (retention time about 10 minutes). The test is not valid unless the resolution factor between the peaks due to impurity A and artemisinin is at least 4. Measure the areas of the peak responses obtained in the chromatograms from solutions (1) and (2) and calculate the percentage content of C15H22O5, using the declared content of C15H22O5 in artemisinin RS with reference to the dried substance. Impurities A.
(3R,5aS,6R,8aS,12S,12aR)-3,6-dimethyl-9-methylideneoctahydro-3,12-epoxypyrano[4,3-j ]-1,2-benzodioxepin-10(3H)-one (artemisitene) B.
(3R,5aS,6R,8aS,9S,12S,12aR)-3,6,9-trimethyloctahydro-3,12-epoxypyrano[4,3-j ]-1,2-benzodioxepin-10(3H)-one (9-epi-artemisinin) |