Alternative methods are given to be used in cases where the required instruments are not available.
Tests and assays are normally carried out at room temperature (between 15 and 25 °C, or up to 30 °C in some climatic zones), unless otherwise indicated.
Any glassware used in pharmacopoeial tests and assays should be of suitable quality.1
1 The following requirements concerning the quality of glass were established by the International Organization for Standardization:
- Glass - Hydrolytic resistance of glass grains at 98 °C - Method of test and classification, Ref. No. ISO 719-1985 (E).
- Glass - Hydrolytic resistance of glass grains at 121 °C - Method of test and classification, Ref. No. ISO 720-1985 (E).
- Glass-ware - Hydrolytic resistance of the interior surfaces of glass containers - Methods of test, Ref. No. ISO 4802-1988 (E).
When a water-bath is referred to in the text, boiling water of about 100 °C is to be used, unless a specific water temperature is given.
Unless otherwise specified, all solutions indicated in the tests and assays are prepared with distilled or demineralized water complying with the monograph for Purified water.